0x99AB PluginControl

Operation Code

0x99AB

Overview

Starts or stops plugin.
(Vendor Expansion Operations)

Operation Parameters as follows.

For RICOH THETA Z1 or later

No. Operation Parameter RICOH THETA Specification
1 Type Kind of action.
(0: start plugin; 1: stop)
2 PluginHandle Target plugin handle.
If no target is specified, then PluginHandle 1 of SetPluginOrders will start. This parameter is ignored when action parameter is 1 (stop).
3 Reserved unused
Specify 0x00000000
4 Reserved unused
Specify 0x00000000
5 Reserved unused
Specify 0x00000000

For RICOH THETA V

No. Operation Parameter RICOH THETA Specification
1 Type Kind of action. Target is the plugin which boot selection is true in GetPluginInfo
(0: start plugin; 1: stop)
2 Reserved unused
Specify 0x00000000
3 Reserved unused
Specify 0x00000000
4 Reserved unused
Specify 0x00000000
5 Reserved unused
Specify 0x00000000

Support model

Z1 V SC S
All v2.21.1 or later